M00 - Cap 60 mm
Description
The Variolab + M00 cover is intended for blinding unused spaces in the range of 60 mm in superstructures for modules
Parameters
Dimensions (H x W):
200 x 60 mm

M01 - Cap 120 mm
Description
The Variolab + M00 cover is intended for blinding unused spaces in the range of 120 mm in superstructures for modules
Parameters
Dimensions (H x W):
200 x 120 mm

M02 - module 2 pcs socket 230 V, 50 Hz, 16 A
Description
The VarioLab + M02 module contains two single 230 V / 16 A sockets protected by an M08 module or an M32 module. The voltage in the sockets is indicated by a light on the module. The sockets are rotated 45 ° for easy handling of the plugs.
Parameters
power voltage:
maximum output current:
dimensions (hxw):
230 V / 50 Hz
16 A total
200 x 120 mm

M03 - connection terminal module for low voltages 5 rows / 5 terminals
Description
The VarioLab + M03 connection terminal module is intended for voltage distribution from laboratory sources to several devices, or for electrical connection of individual products. As standard, the series is supplied in the colors red - black - red - black - blue. Not usable for mains voltage connection!
Parameters
maximum operating voltage:
maximum terminal current:
dimensions (hxw):
30 VDC / 24 V AC
10 A at 30 V DC / 24 V AC
200 x 120 mm

M04 - DC power supply module ± 15 V / 1 A
Description
The VarioLab + M04 module is a source of fixed symmetrical voltage ± 15 V DC / 1 A with an electronic output fuse. The presence of voltage at the output terminals is indicated by separate LEDs.
Parameters
power voltage:
max. output current:
fixed voltage:
typical ripple:
dimensions (hxw):
230 V / 50 Hz
± 1 A
± 15 V
<10 mV
200 x 120 mm

M05 - DC module of laboratory adjustable power supply 1x 0 ÷ 32 V / 4,1 A; 5 V / 3 A
Description
The VarioLab + M05 module is equipped with one source with continuous voltage regulation in the range of 0 ÷ 30 V with the possibility of setting the current limit from 0.1 ÷ 4 A. This model also has a fixed voltage source of 5 V / 3 A. The adjustable part of the source is
equipped with measuring instruments for both voltage and current. The current limit is indicated by a flashing decimal point on the current meter and an intermittent beep. This beep can be turned off as needed.
The outputs of individual sources are controlled by a separate button with a light for easy operation. Thanks to this, it is not necessary to switch off the entire laboratory power supply during work.
Parameters
power voltage:
voltage regulated:
current adjustable:
fixed voltage:
fixed current:
typical ripple:
dimensions (hxw):
230 V / 50 Hz
1x 0 ÷ 30 V
1x 0 ÷ 4 A
1x 5 V
1x 3 A
<2 mV
200 x 180 mm

M06 - RS232 data interface module (COM1 and COM2)
Description
The VarioLab + M06 module works as an extension supply of COM ports from a computer without the need to manipulate the PC at work.
Parameters
cable length (s):
dimensions (hxw):
3 m
200 x 60 mm

M07 - module of output terminals 3x 24 V AC with 3 F circuit breaker
Description
VarioLab + M07 output terminal module for connecting the existing 3x 24 V AC-Y AC distribution. If necessary, transformer (s) can be supplied to create the distribution (parameters must be specified). The output is controlled by a contactor using an M08 or M32 module.
Parameters
power voltage:
maximum output current:
output fuse:
dimensions (hxw):
local distribution or supplied transformer
3x 10 A / 50 Hz
circuit breaker B 3x 10 A
200 x 120 mm

M08-10 - module 1F central switch, fuse 10 A, current protector, TOTAL STOP button
Description
Basic module VarioLab + M08 electrical equipment of NSE superstructures with single-phase distribution of el. current (three-phase wiring see M32), which contains the TOTAL STOP button, power button, circuit breaker, protector, table light switch and indicator light. The module includes a set of buses for connecting other modules that are electrically subordinate to this module. The module is equipped with electronics, which is used for communication with the superior control panel OP-xx. Use of the OP-xx panel is not a requirement.
Parameters
power voltage:
circuit breaker used:
protector used:
dimensions (hxw):
230 V / 50 Hz
1 x C 10 A
30 mA
200 x 120 mm

M08-16 - module 1F central switch, fuse 16 A, current protector, TOTAL STOP button
Description
Basic module VarioLab + M08 electrical equipment of NSE superstructures with single-phase distribution of el. current (three-phase wiring see M32), which contains the TOTAL STOP button, power button, circuit breaker, protector, table light switch and indicator light. The module includes a set of buses for connecting other modules that are electrically subordinate to this module. The module is equipped with electronics, which is used for communication with the superior control panel OP-xx. Use of the OP-xx panel is not a requirement.
Parameters
power voltage:
circuit breaker used:
protector used:
dimensions (hxw):
230 V / 50 Hz
1 x C 16 A
30 mA
200 x 120 mm

M09 - module of stabilized AC / DC power supply 0 V ÷ 255 V / 1 A
Description
The VarioLab + M09 module is a processor-controlled stabilized power supply with an output AC / DC voltage of 0 V ÷ 255 V / 1 A. The output voltage is obtained by transforming the mains voltage 230 V / 50 Hz with an isolating transformer and has a pure sine wave of 50 Hz. The minimum voltage change is 1 V. Limitation of the maximum voltage under the password. Save source states before shutdown. Control via keyboard or personal computer via RS232 interface and D-Control software. With D-Control, time-dependent processes can be defined indefinitely. The set and measured voltage value is displayed on separate three-digit LED displays.
Parameters
power voltage:
max. output current:
voltage regulated, switchable AC / DC:
voltage regulation step:
output frequency:
dimensions (hxw):
230 V / 50 Hz
1 A
0 ÷ 255 V
1 V
50 Hz
200 x 240 mm

M10 - counter and function generator module
Description
The M10 module is a two-channel programmable function generator with a counter, bandwidth 1 μHz ÷ 20 MHz. Counter with a range of 100 mHz ÷ 200 MHz. Utilization of direct digital synthesis (DDS) reducing distortion and noise of the output signal, sampling of 100 MSa / s and 14-bit D / A converter resolution; memory depth 4 k points; 5 standard and 48 preset programmable waveforms. AM, FM, PM,
FSK, lin./log. sweep, burst, USB interface, USB host
Parameters
power voltage:
frequency range:
signal shape:
output impedance:
output amplitude:
Frequency measurement channel A:
sampling:
dimensions (hxw):
230 V / 50 Hz
1 μHz ÷ 20 MHz
sine, rectangle, triangle, saw, b. noise, pulse, DC
50 Ω
2 mV ÷ 10 V at 50 Ω
100 mHz ÷ 200 MHz
100 MSa / s
200 x 240 mm

M11 - Orientation DC voltmeter and ammeter module
Description
Orientation DC voltmeter module up to 48 V DC and ammeter module up to 10 A DC. The module is intended only for teaching electronic connections powered by batteries. The input terminals are made with safety terminals.
Parameters
voltmeter range:
ammeter range:
ammeter load capacity:
Accuracy class of measuring instruments:
dimensions (hxw):
0 ÷ 48 V DC
0 ÷ 10 A DC
over 2 A max. 10 s
2.5
200 x 120 mm

M12 - micro soldering iron module 80 ÷ 450 ° C / 35 W
Description
The VarioLab + M12 module contains a micro soldering iron equipped with a continuous temperature control potentiometer in the temperature range 80 ÷ 450 ° C. The display of the real and set temperature is performed by a clear seven-segment LED display with automatic switching. All operating states of the soldering iron are indicated by three LEDs. Switching of the soldering tip heater is performed
electronically when the AC voltage passes through zero. The soldering iron is equipped with logic for connecting the SBL530.1B automatic cut-out.
Parameters
power voltage:
power consumption:
heater switching:
dimensions (hxw):
pen weight:
230 V / 50 Hz
35 W
at zero
200 x 120 mm
120 g

M13 - DC power supply module 9 V / 1 A
Description
The VarioLab + M13 module is a fixed DC voltage source for powering devices with a voltage of 9 V / 1 A with its own switch and signaling the output voltage by an LED. The voltage is applied to two pairs of instrument terminals.
Parameters
power voltage:
fixed voltage:
fixed current:
typical ripple:
output fuse:
dimensions (hxw):
230 V / 50 Hz
9 V DC
1 A
10 mV
short-circuit proof
200 x 120 mm

M14 - module of double DC laboratory control power supply 2x 0 ÷ 32 V / 4.1 A; 5 V / 3 A
Description
The VarioLab + M14 module is equipped with two sources with continuous voltage regulation in the range 0 ÷ 30 V with the possibility of setting current limitation from 0.1 ÷ 4 A and a fixed voltage source 5 V / 3 A. The adjustable part of the source is equipped with measuring devices for both voltage and for current. The current limit is indicated by a flashing decimal point on the relevant current meter and an intermittent audible signal. The outputs of individual sources are controlled by a separate button with a light for easy operation. It is also equipped with a button for connecting adjustable sources to one symmetrical source.
Parameters
power voltage:
voltage / current regulated:
voltage / current fixed:
typical ripple:
dimensions (hxw):
230 V / 50 Hz
2x 0 ÷ 32 V / 0 ÷ 4.1 A
1x 5 V / 3 A
2 mV
200 x 240 mm

M15 - isolating transformer module 230 V / 230 V / 1.2 A
Description
The VarioLab + module of the M15 isolating transformer is intended for separating the mains voltage from the connected device with a maximum current consumption of 1.2 A. Switching on of the device is indicated by a backlit switch. The output of the device is made by a 230 V panel socket and is protected by a fuse. The transformer is sufficiently dimensioned for continuous supply of the maximum
power to load.
Parameters
power voltage:
maximum output current:
galvanic separation of the output from the power supply network:
output fuse:
dimensions (hxw):
230 V / 50 Hz
1.2 A
yes - 4 kV
T 250 V / 1.25 A
200 x 180 mm

M16 - DC module of laboratory control power supply 1x 0 ÷ 30 V / 10 A
Description
The VarioLab + M16 module is equipped with one source with continuous voltage regulation in the range of 0 ÷ 30 V with the possibility of setting the current limit from 0.1 ÷ 10 A. The adjustable part of the source is equipped with measuring devices for both voltage and current. The current limit is indicated by a flashing decimal point on the current meter and an intermittent beep. This beep can be turned off as needed. The outputs of individual sources are controlled by a separate button with a light for easy operation. Thanks to this, it is not necessary to switch off the entire laboratory power supply during work.
Parameters
power voltage:
voltage / current regulated:
typical ripple:
dimensions (hxw):
230 V / 50 Hz
1x 0 ÷ 30 V / 0 ÷ 10 A
2 mV
200 x 240 mm

M17 - module of 3F hand ammeters 3x 20 A / 40 A
Description
The VarioLab + M17 module is intended for measuring the three-phase current consumption of either the entire body or for measuring the current on the connected module, for example M19, M20, M25, etc. The measuring range is set from 0 ÷ 20 A, The devices measure the effective value of the current in the frequency range of 40 Hz to 100 Hz, but they are calibrated at a frequency of 50 Hz. The devices are equipped with a zero position tumbler, which can be used to set the pointer to the 0 scale mark. The dial of the device is white, the marking is black. The outlets from the module and all connections to the environment are made inside the body.
Parameters
maximum operating voltage:
type of measuring instruments:
ammeter load capacity:
instrument accuracy class:
measuring device:
working frequency:
dimensions (hxw):
400 V AC
analogue
20/40 A AC
1.5
magnetoelectric
40 ÷ 100 Hz
200 x 300 mm

M18 - module 3F circuit breaker and protector for separate protection of power supply modules
Description
The VarioLab + M18 module is intended for securing connected three-phase modules, for example M19, M20. It contains a three-phase circuit breaker 10 A (standard) or 16 A (on request) and a three-phase protector. The outlets from the module and all connections to the environment are made inside the body.
Parameters
maximum operating voltage:
circuit breaker used:
protector used:
dimensions (hxw):
3x 400 V / 50 Hz
3 FB 10 A or 3 FB 16 A
3 F 30 mA
200 x 180 mm

M19 - module of output safety terminals 3 F 400 V
Description
VarioLab + M19 module with safety terminals for 3-phase voltage and three LEDs. Voltage is supplied to the module via the body's internal terminal block. It is suitable to secure the module with a ballast protection module, for example a module M18, M30, M32. The module does not contain its own switch and is necessarily subordinated to the M08 or M32 module for safety reasons, so if the entire body is switched off by these modules, this module is also switched off.
Parameters
maximum operating voltage:
maximum terminal current:
control:
dimensions (hxw):
note:
3 x 400 V / 50 Hz
10 A
only via M08 or M32 module
200 x 120 mm
the module should be secured with a ballast module.

M20 - module 3F socket 16 A + switch
Description
VarioLab + M20 module with three-phase 16 A socket (5 pins), switch and three indicators. Voltage is supplied to the module via the body's internal terminal block. It is suitable to secure the module with a ballast protection module, for example a module M18, M30, M32. For safety reasons, the module is subordinated to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off.
Parameters
maximum operating voltage:
maximum output current:
dimensions (hxw):
note:
3 x 400 V / 50 Hz
16 A
200 x 120 mm
the module should be secured with a ballast module.

M21-06 - module 2 pcs single socket 230 V, 50 Hz, with own circuit breaker 6 A
Description
The VarioLab + M21 module contains two single 230 V CEE 5/7, 16A sockets with its own 6 A circuit breaker. The module does not have its own circuit breaker and is subject to the M08 or M32 module for safety reasons. The voltage in the sockets is indicated by a light on the module. The sockets are rotated 45 ° for easy handling of the plugs.
Parameters
power voltage:
maximum output current:
circuit breaker used:
dimensions (hxw):
230 V / 50 Hz
6 And in total
1 phase B 6 A
200 x 120 mm

M21-10 - module 2 pcs single socket 230 V, 50 Hz, with own circuit breaker 10 A
Description
The VarioLab + M21 module contains two single 230 V CEE 5/7, 16A sockets with its own 10 A circuit breaker. The module does not have its own circuit breaker and is subject to the M08 or M32 module for safety reasons. The voltage in the sockets is indicated by a light on the module. The sockets are rotated 45 ° for easy handling of the plugs.
Parameters
power voltage:
maximum output current:
circuit breaker used:
dimensions (hxw):
230 V / 50 Hz
10 And in total
1 phase B 10 A
200 x 120 mm

M22 - cover 30 mm
Description
The VarioLab + M22 cover is intended for blinding unused fields for modules with a width of 30 mm.
Parameters
dimensions (hxw):
200 x 30 mm
M23 - circuit ringer module
Description
The VarioLab + M23 ring module is designed for easy wire search in a bundle, broken connection or short circuit, connection check, etc. The measurement is performed using the supplied measuring tips. A short circuit is indicated audibly and by a light.
The module has its own power supply using two AA batteries.
Parameters
power voltage:
dimensions (hxw):
3 V DC (2x AA)
200 x 60 mm

M24 - AC power supply module 24 V / 2 A 1 F 1x socket + indicator light + switch
Description
VarioLab + M24 module with one socket under the hinged lid with an output voltage of 24 V AC / 2 A. The module contains a light, a fuse and its own switch. For safety reasons, the module is subordinated to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off.
Parameters
power voltage:
output voltage:
maximum output current:
galvanic separation of the output from the power supply network:
dimensions (hxw):
230 V / 50 Hz
24 V / 50 Hz
2 A
Yes
200 x 120 mm

M25 - module 3 F socket, switch, circuit breaker 3 x 10 A, indicators
Description
VarioLab + M25 module with three-phase 16 A socket (5 pins), switch and three indicators. Voltage is supplied to the module via the body's internal terminal block. The module contains its own protection by a three-phase circuit breaker 10 A (16 A). For safety reasons, the module is subordinated to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off.
Parameters
maximum operating voltage:
maximum output current:
circuit breaker used:
dimensions (hxw):
3x 400 V / 50 Hz
10 A standard / 16 A on request
B 10 A standard / B 16 A on request
200 x 180 mm

M26 - precision multimeter module
Description
The VarioLab + M26 module is a multimeter module measuring the following quantities: AC voltage, DC voltage, AC current, DC current, resistance, capacity, temperature, frequency, inductance. It also contains a ringing function, diode-test.
Parameters
power voltage:
AC voltage:
DC voltage:
AC current:
DC current:
resistance:
capacity:
temperature:
frequency:
dimensions (hxw):
6 x AA pencil batteries
0.4; 4; 40; 400; 750 V
0.4; 4; 40; 400; 1000 V
0.04; 0.4; 10 A
0.004; 0.4; 10 A
400 R; 4; 40; 400 k; 4; 40 M
4; 40; 400 nF; 4; 40; 400 uF; 4; 40 mF
-20 ° ÷ 800 ° C
4; 40; 400 kHz; 4; 40; 400 MHz
200 x 120 mm

Description
The VarioLab + M27 module is a source of fixed symmetrical voltage ± 15 V DC / 1 A and a positive source of +5 V DC / 3 A. Both sources are equipped with an electronic output fuse and a thermal overload fuse. Presence of voltage at the output
terminals is indicated by separate indicators.
Parameters
power voltage:
maximum output current:
typical ripple:
dimensions (hxw):
230 V / 50 Hz
± 1 A; 3 A
<10 mV
200 x 120 mm

M28 - data interface module RS232, LPT, USB
Description
The VarioLab + M28 module works as an extension supply for COM, LPT and USB ports from
computers without the need to manipulate the PC at work.
Parameters
cable length (s):
dimensions (hxw):
3 m
200 x 120 mm

M29 - isolating transformer module 230 V / 230 V / 2.1 A
Description
The VarioLab + module of the M29 isolating transformer is intended for separating the mains voltage from the connected device with a maximum current consumption of 2.1 A. Switching on of the device is indicated by a backlit switch. The output of the device is made by a 230 V panel socket and is protected by a fuse. The transformer is sufficiently dimensioned for continuous supply of the maximum
power to load.
Parameters
power voltage:
maximum output current:
galvanic separation of the output from the power supply network:
output fuse:
dimensions (hxw):
230 V / 50 Hz
2.1 A
yes - 4 kV
T 250 V / 2.5 A
200 x 180 mm

M30 - 3F circuit breaker module
Description
The VarioLab + M30 module is intended for securing connected three-phase modules, for example M19, M20. It contains a three-phase circuit breaker 10 A (standard) or 16 A (on request). The outlets from the module and all connections to the environment are made inside the body.
Parameters
maximum operating voltage:
circuit breaker used:
dimensions (hxw):
3 x 400 V / 50 Hz
3F B10 A or 3F B16 A
200 x 120 mm

M31 - isolating transformer module 230 V / 230 V / 3.0 A
Description
The VarioLab + module of the M31 isolating transformer is intended for separating the mains voltage from the connected device with a maximum current consumption of 3.0 A. Switching on of the device is indicated by a backlit switch. The output of the device is made by a 230 V panel socket and is protected by a fuse. The transformer is sufficiently dimensioned for continuous supply of the maximum
power to load.
Parameters
power voltage:
maximum output current:
galvanic separation of the output from the power supply network:
output fuse:
dimensions (hxw):
230 V / 50 Hz
3.0 A
yes - 4 kV
T 250 V / 3.15 A
200 x 180 mm

M32-10 - module 3F central switch, fuse 3 x 10 A, current protector, TOTAL STOP button
Description
Basic module VarioLab + M32 electrical equipment of NSE superstructures with three-phase distribution of el. current (single-phase distribution see M08), which contains the TOTAL STOP button, power button, circuit breaker, protector, table light switch and indicators. The module includes a set of buses for connecting other modules that are electrically subordinate to this module. The module is equipped with electronics for communication with the superior control panel OP-xx. The use of the OP-xx control panel is not a condition for the function of the module.
Parameters
power voltage:
circuit breaker used:
protector used:
dimensions (hxw):
3x 230/400 V / 50 Hz
3x B 10 A
30 mA
200 x 180 mm

M32-16 - module 3F central switch, fuse 3 x 16 A, current protector, TOTAL STOP button
Description
Basic module VarioLab + M32 electrical equipment of NSE superstructures with three-phase distribution of el. current (single-phase distribution see M08), which contains the TOTAL STOP button, power button, circuit breaker, protector, table light switch and indicators. The module includes a set of buses for connecting other modules that are electrically subordinate to this module. The module is equipped with electronics for communication with the superior control panel OP-xx. The use of the OP-xx control panel is not a condition for the function of the module.
Parameters
power voltage:
circuit breaker used:
protector used:
dimensions (hxw):
3x 230/400 V / 50 Hz
3x B 16 A
30 mA
200 x 180 mm

M33 - DC module of laboratory adjustable power supply 1x 0 ÷ 30 V / 20 A
Description
The VarioLab + M33 module is equipped with one source with continuous voltage regulation in the range of 0 ÷ 30 V with the possibility of setting the current limit from 0.1 ÷ 20 A. The adjustable part of the source is equipped with measuring devices for both voltage and current. The current limit is indicated by a flashing decimal point on the current meter and an intermittent beep. This beep can be turned off as needed. The output of the source is controlled by a separate button with a light for its easy operation. Thanks to this, it is not necessary to switch off the entire laboratory power supply during work. The output is equipped with a reversible thermal fuse.
Parameters
power voltage:
voltage regulated:
current adjustable:
typical ripple:
maximum ripple:
dimensions (hxw):
230 V / 50 Hz
1x 0 ÷ 30 V
1x 0 ÷ 20 A
<2 mV
17 mV
200 x 390 mm

M34 - module of input hand UI AC meters 250 V; 15 A
Description
The VarioLab + M34 module is used for immediate control of the single-phase input voltage of the body and the total current consumption of all appliances located and connected to the body. Upon agreement, the module can only be connected to measure a certain part of the body or a single module, such as the M02 module. By connecting to the module, the voltage and current drawn by the module can then be measured.
Parameters
maximum operating voltage:
type of measuring instruments:
instrument accuracy class:
measuring device:
working frequency:
indicator deviation:
scale length:
dimensions (hxw):
250 V AC [U]; 400 V AC [A]
analogue
1.5
magnetoelectric
40 ÷ 100 Hz
80 °
57.2 mm
200 x 120 mm

M35 - module 1 pc single socket 230V + 1 pc PC socket 230 V, 50 Hz, 10 A
Description
The VarioLab + M35 module contains one simple single-phase 230 V / 10 A socket and one single-phase 230 V / 6 A device socket. The module is protected by an M08 module or an M32 module. The voltage in the sockets is indicated by a light on the module.
Parameters
power voltage:
maximum output current:
dimensions (hxw):
230 V / 50 Hz
10 And in total
200 x 120 mm

M36 - module of connecting safety terminals (6 rows)
Description
The VarioLab + M36 connection terminal module is intended for voltage distribution from laboratory sources to several devices, or for electrical connection of individual products. As standard, the series is supplied in the colors 2x red, 2x black, 2x blue. The terminals can also be used for 230 V mains voltage.
Parameters
maximum operating voltage:
maximum terminal current:
dimensions (hxw):
120 V DC / 230 V AC
10 A at 30 V DC / 24 V AC
200 x 120 mm

M37 - module of double 3F safety sockets 3x 400 V, circuit breaker 10 A, TOTAL STOP button
Description
The VarioLab + M37 module is designed as a voltage source of 3x 400 V / 10 A. The module has its own 3F B10 A circuit breaker and its own on-off control with buttons. The presence of voltage on the output sockets is indicated by LEDs. Voltage is applied to the safety sockets connected in parallel. For safety reasons, the module is subordinated to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off.
Parameters
maximum operating voltage:
maximum output current:
maximum terminal current:
dimensions (hxw):
3 x 400 V / 50 Hz
10 A
10 A
200 x 180 mm

M38 - data interface module RS232, LPT, USB, LAN-RJ45
Description
The VarioLab + M38 module works as an extension supply for COM, LPT and USB ports from a computer without the need to manipulate the PC at work. It is also equipped with a LAN RJ-45 category 5 socket.
Parameters
cable length (s):
dimensions (hxw):
3 m
200 x 60 mm

M39 - LAN switch module 10 / 100MB, 5 ports
Description
The VarioLab + M39 module is used to easily connect various devices to a computer network. It contains a five-port switch and one connection port to a computer network. Operation is indicated by LEDs. The transfer rate is 10/100 Mbps. For safety reasons, the module is subordinated to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off.
Parameters
number of output ports:
baud rate:
dimensions (hxw):
5
10/100 Mbps
200 x 60 mm

M40 - USB replicator module for 4 connection points
Description
The VarioLab + M40 module is used to expand the USB port to 4 USB outputs. Signaling of the data connection with the PC is performed by a green LED, signaling of the presence of the supply voltage by a red LED. For safety reasons, the module is subordinated to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off.
Parameters
power voltage:
cable length (s):
dimensions (hxw):
230 V / 50 Hz
3 m
200 x 60 mm

M41 - module of double DC laboratory control power supply 2x 0 ÷ 42 V / 3.1 A; 5 V / 3 A
Description
The VarioLab + M41 module is equipped with two sources with continuous voltage regulation in the range 0 ÷ 40 V with the possibility of setting current limitation from 0.1 ÷ 3 A and a fixed voltage source 5 V / 3 A. The adjustable part of the source is equipped with measuring devices for both voltage and for current. The current limit is indicated by a flashing decimal point on the relevant current meter and an intermittent audible signal. The outputs of individual sources are controlled by a separate button with a light for easy operation. It is also equipped with a button for connecting adjustable sources to one symmetrical source.
Parameters
power voltage:
voltage / currentregulated:
voltage / current fixed:
typical ripple:
dimensions (hxw):
230 V / 50 Hz
2x 0 ÷ 42 V / 0 ÷ 3.1 A
1x 5 V / 3 A
2 mV
200 x 240 mm

M42 - DC module of laboratory adjustable power supply 1x 0 ÷ 42 V / 3.1 A; 5 V / 3 A
Description
The VarioLab + M41 module is equipped with two sources with continuous voltage regulation in the range 0 ÷ 40 V with the possibility of setting current limitation from 0.1 ÷ 3 A and a fixed voltage source 5 V / 3 A. The adjustable part of the source is equipped with measuring devices for both voltage and for current. The current limit is indicated by a flashing decimal point on the relevant current meter and an intermittent audible signal. The outputs of individual sources are controlled by a separate button with a light for easy operation. It is also equipped with a button for connecting adjustable sources to one symmetrical source.
Parameters
power voltage:
voltage / currentregulated:
voltage / current fixed:
typical ripple:
dimensions (hxw):
230 V / 50 Hz
2x 0 ÷ 42 V / 0 ÷ 3.1 A
1x 5 V / 3 A
2 mV
200 x 240 mm

M43 - DC stabilized power supply module ± 24 V / 1 A
Description
The VarioLab + M43 module is a source of fixed symmetrical stabilized voltage ± 24V DC / 1 A with an electronic output fuse. The presence of voltage at the output terminals is indicated by separate LEDs.
Parameters
power voltage:
max. output current:
fixed voltage:
typical ripple:
dimensions (hxw):
230 V / 50 Hz
± 1 A
± 24 V
<10 mV
200 x 120 mm

M44 - module of stabilized AC / DC power supply 0 V ÷ 255 V / 2 A
Description
The VarioLab + M44 module is a processor-controlled stabilized AC / DC power supply with an output voltage of 0 V ÷ 255 V / 2 A. The output voltage is obtained by transforming the mains voltage 230 V / 50 Hz with an isolating transformer and has a pure sine wave of 50 Hz. The minimum voltage change is 1 V. Limitation of the maximum voltage under the password. Save source states before shutdown. Control via keyboard or personal computer via RS232 interface and D-Control software. With D-Control, time-dependent processes can be defined indefinitely. The set and measured voltage value is displayed on separate three-digit LED displays.
Parameters
power voltage:
max. output current:
voltage regulated, switchable AC / DC
voltage regulation step:
output frequency:
dimensions (hxw):
230 V / 50 Hz
2 A
0 ÷ 255 V
1 V
50 Hz
200 x 240 mm

M45 - isolating transformer module 230 V / 230 V / 10 A
Description
The VarioLab + module of the M45 isolating transformer is intended for separating the mains voltage from the connected device with a maximum current consumption of 10 A. Switching on of the device is indicated by a backlit switch. The output of the device is made by a 230 V panel socket and is protected by a fuse. The transformer is sufficiently dimensioned for a continuous supply of maximum power to the load.
Parameters
power voltage:
maximum output current:
galvanic separation of the output from the power supply network:
output fuse:
dimensions (hxw):
230 V / 50 Hz
10 A
yes - 4 kV
T 250 V / 12.5 A
200 x 240 mm


M46 - isolating transformer module 230 V / 230 V / 5 A
Description
The VarioLab + module of the M46 isolating transformer is intended for separating the mains voltage from the connected device with a maximum current consumption of 5 A. Switching on of the device is indicated by a backlit switch. The output of the device is made by a 230 V panel socket and is protected by a fuse. The transformer is sufficiently dimensioned for a continuous supply of maximum power to the load.
Parameters
power voltage:
maximum output current:
galvanic separation of the output from the power supply network:
output fuse:
dimensions (hxw):
230 V / 50 Hz
5 A
yes - 4 kV
T 250 V / 6.3 A
200 x 180 mm

M47 - module of unstabilized unfiltered DC power supply 24 V / 4.5 A
Description
The VarioLab + M47 module is a fixed source of DC, unstabilized and unfiltered voltage 24 V / 4.5 A with its own switch and signaling of the output voltage by an LED indicator. Voltage is applied to the instrument terminals. Input and output fuse.
Parameters
power voltage:
fixed voltage:
fixed current:
output fuse:
dimensions (hxw):
230 V / 50 Hz
24 V DC
4.5 A
fuse T 250 V / 5 A
200 x 120 mm

M48 - DC module of laboratory control power supply 1x 0 ÷ 40 V / 10 A
Description
The VarioLab + M48 module is equipped with one source with continuous voltage regulation in the range of 0 ÷ 40 V with the possibility of setting the current limit from 0.1 ÷ 10 A. The adjustable part of the source is equipped with measuring devices for both voltage and current. The current limit is indicated by a flashing decimal point on the current meter and an intermittent beep. This beep can be turned off as needed. The outputs of individual sources are controlled by a separate button with a light for easy operation. Thanks to this, it is not necessary to switch off the entire laboratory power supply during work.
Parameters
power voltage:
voltage / current regulated:
typical ripple:
dimensions (hxw):
230 V / 50 Hz
1x 0 ÷ 40 V / 0 ÷ 10 A
2 mV
200 x 240 mm

M49 - compressed air outlet module with 2.5 bar precision pressure reducing valve
Description
The VarioLab + module of the regulated compressed air outlet with a precision M49 control valve is intended for the connection of various pneumatic components such as pneumatic tools, spray guns and other devices requiring compressed air for their function. The module is equipped with a precision pressure reducing valve 0 ÷ 2.5 bar, manometer, one gland without regulation and two glands of adjustable air. The module has a main air shut-off valve, which can be used to close the compressed air supply and thus switch off the entire module. The module is connected to the existing compressed air distribution.
Parameters
air inlet pressure:
outlet pressure unregulated:
outlet pressure regulated:
output:
dimensions (hxw):
3.0 ÷ 12.0 bar
dependent on inlet pressure
0 ÷ 2.5 bar
quick coupling for hoses dia. 6 mm
200 x 240 mm

M50 - compressed air outlet module with precision pressure reducing valve 10.0 bar
Description
The VarioLab + module of the regulated compressed air outlet with a precision M49 control valve is intended for the connection of various pneumatic components such as pneumatic tools, spray guns and other devices requiring compressed air for their function. The module is equipped with a precision pressure reducing valve 0 ÷ 10 bar, a manometer, one gland without regulation and two glands with adjustable air. The module has a main air shut-off valve, which can be used to close the compressed air supply and thus switch off the entire module. The module is connected to the existing compressed air distribution.
Parameters
air inlet pressure:
outlet pressure unregulated:
outlet pressure regulated:
output:
dimensions (hxw):
10.0 ÷ 12.0 bar
dependent on inlet pressure
0 ÷ 10 bar
quick coupling for hoses dia. 6 mm
200 x 240 mm
M51 - three-phase autotransformer module 3x 230 V / 400 V / 2 A

Description
The VarioLab + M51 module is equipped with one three-phase adjustable AC power supply, not separated from the mains, in the range of 3x <5 ÷ 230 V with a maximum current consumption of 2.0 A. The power supply is protected by reversible fuses. Switching on the power supply is indicated by a backlit switch and at the same time the individual phases have their own LEDs. The power supply is output by safety terminals. The output voltage and current values are displayed on analog measuring instruments. The transformer is sufficiently dimensioned for a continuous supply of maximum power to the load.
Parameters
power voltage:
output voltage:
maximum output current:
insurance:
dimensions (hxw):
The power supply output is not galvanically isolated!
3x 230 V / 50 Hz, Y
3x <5 ÷ 230 V, Y
3x 2.0 A
return fuse 2.5 A
200 x 450 mm

M52 - autotransformer module 230 V / 2 A with the possibility of switching AC / DC
Description
The VarioLab + M52 module is equipped with one single-phase adjustable, non-isolated AC power supply in the range <5 ÷ 230 V with a maximum current consumption of 2.0 A.
At the same time, it can be switched with the switch to a DC unfiltered power supply <5 ÷ 230 V. The power supply is protected by a return fuse. Switching on the power supply is indicated by a backlit switch and a regulated voltage indicator light. The power supply is output by safety terminals. The output voltage and current values are displayed on analog measuring instruments. The transformer is sufficiently dimensioned for a continuous supply of maximum power to the load.
Parameters
power voltage:
output voltage:
maximum output current:
insurance:
dimensions (hxw):
The power supply output is not galvanically isolated!
230 V / 50 Hz
<5 ÷ 230 V AC / DC
2.0 A
return fuse 2.5 A
200 x 240 mm

M53 - module of unstabilized unfiltered DC power supply 6 - 12 - 24 - 48 V / 2.0 A
Description
The VarioLab + M53 module is a fixed source of DC, unstabilized and unfiltered voltage with the possibility of switching the value of the output voltage in the range of 6 - 12 - 24 - 48 V / 2.0 A with a rotary switch. The power supply is equipped with its own switch and output voltage signaling by LED indicator. Voltage is applied to the safety instrument terminals. Secured by an input fuse.
Parameters
power voltage:
output voltage:
fixed current:
input protection:
dimensions (hxw):
230 V / 50 Hz
6 - 12 - 24 - 48 V DC
2 A
fuse T 250 V / 0.4 A
200 x 120 mm

M54 - module 2 pcs SCHUKO socket 230 V, 50 Hz, 16 A
Description
The VarioLab + M54 module contains two simple schuko sockets 230 V / 16 A protected by an M08 module or an M32 module. The voltage in the sockets is indicated by a light on the module. The sockets are rotated 45 ° for easy handling of the plugs.
Parameters
power voltage:
maximum output current:
dimensions (hxw):
230 V / 50 Hz
16 A
200 x 120 mm

M55 - module 2pcs SCHUKO socket 230 V, 50 Hz, 6 A + own circuit breaker
Description
The VarioLab + M55 module contains two simple 230 V / 6 A schuko sockets with their own circuit breaker. The module does not contain its own switch and is, for safety reasons, subordinate to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off. The voltage in the sockets is indicated by a light on the module. The sockets are rotated 45 ° for easy handling of the plugs.
Parameters
power voltage:
maximum output current:
circuit breaker used:
dimensions (hxw):
230 V / 50 Hz
16 A
6 A
200 x 120 mm

M56 - 30 MHz digital two-channel oscilloscope module with color LCD display
Description
The VarioLab + M56 module is a digital two-channel real-time oscilloscope with a measured bandwidth of 30 MHz. Record up to 5000 points for each channel. Twenty automatic measuring functions. USB communication. Saving and viewing waveforms. Computational functions. Color LCD display with high resolution and contrast. The delivery also includes two measuring cords.
Parameters
bandwidth:
sampling frequency:
input:
input impedance:
max. input voltage:
record length:
display size:
dimensions (hxw):
30 MHz
100 MS / s
DC, AC, GND
1 MOhm ± 2% in parallel with 20 pF ± 5 pF
300 V šp - šp
5000 points per channel
7.8 ”, 640 x 480 pixels
200 x 420 mm

M57 - 100 MHz digital two-channel oscilloscope module with color LCD display
Description
The VarioLab + M57 module is a digital two-channel real-time oscilloscope with a measured bandwidth of 100 MHz. Record up to 5000 points for each channel. Twenty automatic measuring functions. USB communication. Saving and viewing waveforms. Computational functions. Color LCD display with high resolution and contrast. The delivery also includes two measuring cords
Parameters
bandwidth:
sampling frequency:
input:
input impedance:
max. input voltage:
record length:
display size:
dimensions (hxw):
100 MHz
500 MS / s
DC, AC, GND
1 MOhm ± 2% in parallel with 15 pF ± 5 pF
300 V šp - šp
6000 points per channel
8 ”, 640 x 480 pixels
200 x 420 mm

M58 - cover 240 mm
Description
The VarioLab + M58 cover is intended for blinding unused fields for 240 mm wide modules.
Parameters
dimensions (hxw):
200 x 420 mm

M59 - single-phase circuit breaker module
Description
The VarioLab + M59 module is intended for securing connected single-phase modules and external sockets. It contains a single-phase circuit breaker 10 A (standard) or 16 A (on request) with characteristic B. The terminals from the module and all connections to the environment are made inside the body.
Parameters
maximum operating voltage:
circuit breaker used:
dimensions (hxw):
1 x 230 V / 50 Hz
1F B10 A or 1F B16 A
200 x 60 mm

M60 - module of digital 4 and ½ digit multimeter U - I - R - hfe - Hz
Description
• Dual 50,000 digit display (main) for simultaneous indication of UAC and Hz, UDC (UAC) and dBm or UDC and UAC ripple
• Measurement of UDC, UAC, IDC, IAC, R, C, f, continuity, diodes, dBm
• HOLD, MAX / MIN, REL, COMPARE functions
• Manual or automatic range switching
• Basic accuracy 0.03% for UDC
• In the UAC measurement range up to 50 kHz
• High current measuring range up to 20 A
• AC TRUE RMS or AC + DC TRUE RMS measurement
Parameters
power voltage:
AC voltage:
DC voltage:
AC current:
DC current:
frequency:
resistance:
dimensions (hxw):
230 V / 50 Hz
0.5; 5; 50; 500; 1000 V
0.5; 5; 50; 500; 1000 V
0.5 mA - 20 A
0.5 mA - 0.5 A; 2 A - 20 A
10 Hz - 50 kHz; 50 kHz - 150 kHz
500 R; 5 k; 500 k; 5 M; 20 M
200 x 240 mm
M61 - 3F transformer module 1x AC 24 V / 2 A / D, 1x AC 24 V / 42 V / 2 AY / D
Description
The VarioLab + M61 module contains two separate AC voltage sources with an output current of 2 A. One source in connection D with an output voltage of 3x 24 V and one source in connection Y / D with an output voltage of 24/42 V. The outputs are made with safety terminals. The module contains its own switch with a light and is, for safety reasons, subordinate to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off. The module contains an input circuit breaker.
Parameters
power voltage:
output voltage 1:
output voltage 2:
maximum output current:
circuit breaker used:
dimensions (hxw):
3x 230 V / 400 V / 50 Hz
AC 24 V - D
AC 24 V / 42 V - Y
2 A
3F B2 A
200 x 240 mm

M62 - stabilized DC power supply module 5 - 12 - 24 - 48 V / 2 A
Description
The VarioLab + M62 module contains four separate stabilized DC power supplies with their own outputs 5 - 12 - 24 - 48 V. Each of the power supplies is able to supply 2 A current to the load. The outputs are made by safety terminals and are protected by an electronic fuse. The module contains the main mains fuse, switch and indicator light.
Parameters
power voltage:
output voltage 1:
output voltage 2:
output voltage 3:
output voltage 4:
output current of each source:
dimensions (hxw):
230 V / 50 Hz
5 V DC
12 V DC
24 V DC
48 V DC
2 A
200 x 180 mm

M63 - TOTAL STOP button module
Description
The VarioLab + M63 module, TOTAL STOP button, is designed to increase safety in classrooms and workshops, where all VarioLab + workplaces must be switched off at the same time in the event of danger. By installing it and connecting it to other VarioLab + workplaces, all workplaces can be switched off. This module does not replace the M08 and M32 central switch and fuse modules.
Parameters
control voltage:
maximum current by button:
dimensions (hxw):
230 V / 50 Hz
2 A
200 x 60 mm

M64 - autotransformer module 230 V / 3 A with the possibility of switching AC / DC
Description
The VarioLab + M64 module is equipped with one single-phase adjustable, non-isolated AC power supply in the range <5 ÷ 230 V with a maximum current consumption of 3.0 A. At the same time it can be switched to DC unfiltered power supply <5 ÷ 230 V. The power supply is protected tubular fuse. Switching on the power supply is indicated by a backlit switch and a regulated voltage indicator light.
The power supply is output by safety terminals. The output voltage and current values are displayed on analog measuring instruments. The transformer is sufficiently dimensioned for a continuous supply of maximum power to the load.
Parameters
power voltage:
output voltage:
maximum output current:
insurance:
dimensions (hxw):
The power supply output is not galvanically isolated!
230 V / 50 Hz
<5 ÷ 230 V AC / DC
3.0 A
fuse T3.15 A
200 x 240 mm

M65 - AC 230 V / 10 A terminal module, 2x socket, euroconnector, safety terminals + circuit breaker
Description
The VarioLab + M65 module is designed as a voltage source of 230 V / 10 A. The module has its own circuit breaker B 10 A. The presence of voltage on the output sockets is indicated by LEDs. The voltage is output to two sockets, a euro connector and a safety socket. For safety reasons, the module is subordinated to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off.
Parameters
maximum operating voltage:
maximum output current:
maximum terminal current:
dimensions (hxw):
1 x 230 V / 50 Hz
10 A
10 A
200 x 180 mm

M66 - reversing module 3F / 400 V / 16 A
Description
The M66 module is designed for reversing the connected three-phase motor with a maximum current consumption of 10 A. The module is equipped with a 3F circuit breaker 10 A and indicators for left and right motor operation. The output voltage is connected to safety sockets and two three-phase 16 A sockets.
Parameters
power voltage:
maximum output current:
maximum terminal current:
insurance:
dimensions (hxw):
3x 230 V / 400 V / 50 Hz
10 A
10 A
3F B10 A
200 x 240 mm

M67 - power supply module AC 24 V / 2 A 1F 1x socket + safety sockets + indicator light + switch
Description
VarioLab + M24 module with safety sockets and one socket under the hinged lid with an output voltage of 24 V AC / 2 A. The module contains a light, a fuse and its own switch. For safety reasons, the module is subordinated to the M08 or M32 module, so if the entire body is switched off by these modules, this module is also switched off.
Parameters
power voltage:
output voltage:
maximum output current:
galvanic separation of the output from the power supply network:
dimensions (hxw):
230V / 50 Hz
24 V / 50 Hz
2 A
Yes
200 x 120 mm

M68 - storage space 240 mm continuous
Description
With the help of the storage space, it is possible to create a place in the instrument body in which items of daily use in the workplace can be stored. It is designed so that A4 catalogs can also be stored in it. Can only be used in conjunction with M69 modules. Their combination can create a space of different widths.
Parameters
internal height:
internal depth:
dimensions (hxw):
161 mm
285 mm
200 x 240 mm

M69 - storage space 240 mm extreme
Description
With the help of the storage space, it is possible to create a place in the instrument body in which items of daily use in the workplace can be stored. It is designed so that A4 catalogs can also be stored in it. Can only be used in conjunction with a second M69 module or an M68 module. Their combination can create a space of different widths.
Parameters
internal height:
internal depth:
orientation:
dimensions (hxw):
161 mm
285 mm
left and right
200 x 240 mm

M70 - storage space 240 mm closed
Description
With the help of a storage enclosed space, it is possible to create a place in the instrument body in which items of daily use in the workplace can be stored. It is designed so that A4 catalogs can also be stored in it. It is designed for separate installation in the instrument body.
Parameters
internal height:
internal depth:
dimensions (hxw):
161 mm
285 mm
200 x 240 mm

M71 - resistance decade module
Description
The VarioLab + M71 module is a resistance decade in the range 1Ω ÷ 999999 Ω. The resulting value is selected with the "+" and "-" buttons on the given switch order. The set value is shown on the mechanical display of the switch. The output is made by safety sockets.
Parameters
range:
smallest change in value:
maximum supply voltage:
maximum power dissipation:
tolerance
temperature coefficient:
dimensions (hxw):
1 ÷ ÷ 999999 Ω
1 Ω
30 V DC / 50 V AC
1 W
<1%
50 ppm / K
200 x 120 mm

M72 - induction decade module
Description
The VarioLab + M72 module is an induction decade in the range of 1 uH ÷ 99.999 mH. The resulting value is selected with the "+" and "-" buttons on the given switch order. The set value is shown on the mechanical display of the switch. The output is made by safety sockets.
Parameters
range:
smallest change in value:
maximum supply voltage:
maximum current:
tolerance 1 uH - 999 uH:
tolerance 1 mH - 99 mH:
dimensions (hxw):
1 uH ÷ 99.999 mH
1 uH
30 V DC / 50 V AC
0.1 A
<10%
<5%
200 x 120 mm

M73 - capacitive decade module
Description
The VarioLab + M73 module has a capacitance decade in the range of 10 pF ÷ 999.99 nF. The resulting value is selected with the "+" and "-" buttons on the given switch order. The set value is shown on the mechanical display of the switch. The output is made by safety sockets.
Parameters
range:
smallest change in value:
maximum supply voltage:
tolerance:
dimensions (hxw):
10 pF ÷ 999.99 nF
10 pF
50 V DC / 50 V AC
<10%
200 x 120 mm

M74 - module of resistance, induction and capacitance decade
Description
The VarioLab + M74 module is a decade with three independent sections for resistance, inductance and capacitance. The range of values for resistance is 1 Ω ÷ 999999 Ω, for inductance 1 uH ÷ 99.999 mH and for capacitance 10 pF ÷ 999.99 nF. The individual quantities are galvanically separated from each other and have separate outputs. The values for each order of values and quantity are selected with the "+" and "-" buttons on the given order of the switch separately. The set value is shown on the mechanical display of the switch. The output is made by safety sockets.
Parameters
resistance decade:
induction decade:
resistance decade:
dimensions (hxw):
see module M71
see module M72
see module M73
200 x 120mm

M75- autotransformer module 230 V / 6 A with the possibility of switching AC / DC
Description
The VarioLab + M64 module is equipped with one single-phase adjustable AC power supply, not separated from the mains, in the range <5 ÷ 230 V with a maximum current consumption of 6.0 A. At the same time, it can be switched by switch to DC unfiltered power supply <5 ÷ 230 V. The power supply is protected tubular fuse. Switching on the power supply is indicated by a backlit switch and a regulated voltage indicator light. The power supply is output by safety terminals. The output voltage and current values are displayed on analog measuring instruments. The transformer is sufficiently dimensioned for a continuous supply of maximum power to the load.
Parameters
power voltage:
output voltage:
maximum output current:
insurance:
dimensions (hxw):
The power supply output is not galvanically isolated!
230 V / 50 Hz
<5 ÷ 230 V AC / DC
6.0 A
fuse T 6 A
200 x 240 mm

M76- 3F motor start-up module 3x400V, with manual Y / D switching
Description
The VarioLab + M76 module is equipped with a contactor combination with push-button control for starting a 3-phase electric motor in Y / D mode with manual Y / D switching. The module contains protection by 3 phase circuit breaker 10 A / C, signaling of switching on by three red lights. The power supply output is to a five-pole socket 3x 16A and at the same time to sockets L1, L2, L3, N, PE.
Parameters
power voltage:
power on signaling:
maximum output current:
insurance:
dimensions (hxw):
3x 400 V / 230 V / 50 Hz
3 lights
3x 10 A
3 phase circuit breaker 3x 10 A / C
200 x 240 mm

M77- Module of series-connected capacitors 1000 uF + 1000 uF / 500 uF / 400 V with center output
Description
The module with capacitors for voltages up to 400 V and capacities of 2 x 1000 uF and 1 x 500 uF is intended for laboratory experiments with rotating machines. Rows of terminals in black, blue and red are supplied as standard. Due to the capacitor used, the module can be used for mains voltages up to 400V. This module is completely autonomous, without direct electrical connection to other devices or table modules.
Parameters
maximum voltage:
elements included:
dimensions (hxw):
400 V
capacitors 2 x 1000 uF and 1 x 500 uF / 400 V
200 x 240 mm

M78- Cam rotary switch module 3 x 400 V / 20 A
Description
The M78 module contains one separate cam switch for a maximum alternating voltage of 3 x 400 V and a current of up to 20 A. The module is suitable as a switch for the power supply to the body or for switching external equipment.
Parameters
maximum switching voltage:
maximum switching current:
dimensions (hxw):
3 x 400/230 V AC
20 A AC
200 x 120 mm

M79- Capacitor module 1000 uF / 100 V
Description
The module with a capacitor for voltage up to 100 V and a capacity of 1000 uF is designed for laboratory experiments with rotating machines. Rows of terminals in black and red are supplied as standard. Due to the capacitor used, the module can be used for mains voltages up to 100V. This module is completely autonomous, without direct electrical connection to other devices or table modules.
Parameters
maximum voltage:
elements included:
dimensions (hxw):
100 V
capacitor 1000 uF
200 x 60 mm

M80- 3F rectifier module 600 V / 20 A (six-pulse)
Description
Six-pulse rectifier module (6 diodes) with 5 terminals, maximum current on diodes 20A. As standard, the terminals are supplied in a series of black and red. Voltage is supplied to the module via the input terminals of the module, so this module is completely autonomous, without direct electrical connection to other devices or table modules. The terminals can be used for mains voltages up to 600V.
Parameters
maximum voltage:
maximum current:
dimensions (hxw):
600 V AC
20 A (maximum current on diodes)
200 x 60 mm

M82- Module 3F analog voltmeters (230V), ammeters (10A) and output sockets
Description
The VarioLab + M82 module is intended for measuring the voltage at the output of the autotransformer and the consumption of three-phase current. The voltage measurement range is set from 0 ÷ 250V and current from 0 ÷ 10A, with the proviso that ammeters can be momentarily overloaded. The devices measure the effective value of the current in the frequency range 40 to 100Hz, but they are calibrated at a frequency of 50Hz. The devices are equipped with a zero position tumbler, which can be used to set the pointer to the 0 scale mark. The dial of the device is white, the marking is black. The outlets from the module are made to the safety sockets on the panel.
Parameters
maximum operating voltage:
type of measuring instruments:
ammeter load capacity:
instrument accuracy class:
measuring device:
working frequency:
dimensions (hxw):
250 V AC
analog
10/15 A AC
1.5
magnetoelectric
40 ÷ 100 Hz
200 x 240mm

M83- Module of four sockets 230 V CEE 5/7, 16A
Description
The M83 module contains a total of four CEE 5/7 compliant mains sockets with an earth pin. The sockets serve, similarly to the M02 module, for powering electrical devices, which are thus connected via the VarioLab + table fuse. If the power supply to the table is switched off, the sockets in the M83 module are also de-energized.
Parameters
operating voltage:
maximum current:
dimensions (hxw):
230 V AC / 50 Hz
16 A
200 x 150 mm

M84- Data interface module 2 x USB, 1 x LAN-RJ45, 1 x HDMI
Description
The M84 data interface module contains 2 x USB, 1 x LAN-RJ45, 1 x HDMI. It is delivered including connection cables 2 x USB 3m, 1 x LAN UTP Cat5e 5m, HDMI cable is not included.
Parameters
connectors:
dimensions (hxw):
2 x USB, 1 x LAN-RJ45, 1 x HDMI
200 x 60 mm

M85- Data interface module 2 x USB, 1 x LAN-RJ45
Description
The M85 data interface module contains 2 x USB, 1 x LAN-RJ45. It is supplied including connection cables 2 x USB 3m, 1 x LAN UTP Cat5e 5m.
Parameters
connectors:
dimensions (hxw):
2 x USB, 1 x LAN-RJ45
200 x 60 mm

M86- Packet switch module 3f, 400V / 63A
Description
The M78 module contains one separate cam switch for a maximum alternating voltage of 3 x 400 V and a current of up to 63 A. The module is suitable as a switch for the power supply to the body or for switching external equipment.
Parameters
maximum switching voltage:
maximum switching current:
dimensions (hxw):
3 x 400 V
3 x 63 A AC
200 x 120 mm

M87- AC power supply module 6 - 12 - 24 V / 2A
Description
The VarioLab + M86 module is a fixed source of low AC voltage with the possibility of switching the value of the output voltage in the range of 6 - 12 - 24 V / 2.0 A with a rotary switch. The power supply is equipped with its own switch and output voltage signaling by LED indicator. Voltage is applied to the safety instrument terminals. Secured by an input fuse.
Parameters
power voltage:
output voltage:
fixed current:
input protection:
dimensions (hxw):
230 V / 50 Hz
6 - 12 - 24 V DC
2 A
fuse T 250 V / 0.4 A
200 x 120 mm
M88- Simple tester module with switches
Description
The VarioLab + M87 module is a simple tester that consists of three separate pairs of sockets with two-position switches. Each switch allows you to choose from two components (eg resistors, capacitors, or inductors of different values according to customer specifications).
Parameters
maximum voltage:
maximum current:
dimensions (hxw):
depends on the components used, a maximum of 230 V AC and 120 V DC
depends on the components used, maximum 10 A
200 x 120 mm

M89- Programmable network analyzer module (A, V, W, f), RS-232 output
Description
The M89 module is a universal AC VA meter with an extension with functions for further network analysis. The device measures voltage, current, active power, frequency and calculates reactive power, apparent power and cos fi. The basis of the device is a single-chip microcontroller and a true RMS converter, which guarantees the device good accuracy, stability and easy operation. Insulation resistance meter, AC / DC voltage, and resistance, large display of 6000 units. The power supply of the module from the instrument body is subordinated to the M08 or M32 module.
Parameters
power voltage:
ranges:
data output:
dimensions (hxw):
80… 250 V AC / DC
0… 10/120/250/450 V
RS232
200 x 120 mm

M90- Single-phase socket module with power measurement
Description
The M90 module contains one single-phase socket, supplemented by an electronic monitoring device that can measure the parameters of electrical appliances to 230 V AC and a maximum power input of 3680 W. The module measures voltage, current and frequency (Hz) and displays on the 3-line LCD display also active (effective) performance of electrical appliances, their
apparent power (input), reactive power and consumed electrical energy. The power supply of the module from the instrument body is subordinated to the module M08, respectively M32.
Parameters
power voltage:
maximum current consumption:
power measurement:
consumption measurement:
dimensions (hxw):
230 V AC / 50 Hz
16 A
0.1 to 3680 W
0.000 to 9,999 kWh
200 x 120 mm

M91- Module of three digital voltmeters 10 - 600 V AC
Description
The M91 module contains three independent digital voltmeters for measuring AC voltage over a wide range of values. It measures the effective value of voltage and stores in memory min. and max. values. In the event of a power failure, the measured data will remain in memory. The power supply of the module from the instrument body is subordinated to the M08 or M32 module.
Parameters
power voltage:
voltage measurement in the range:
accuracy:
network connection:
dimensions (hxw):
230 V AC / 50 Hz
10 - 600 V AC
1% +/- 1 digit
1 phase, two-wire (each of the devices separately)
200 x 240 mm

M92- Module of three digital ammeters 70 mA - 200 A AC
Description
The M92 module contains three independent digital ammeters for measuring AC current over a wide range of values. It measures the effective value of the current and stores the maximum, average and instantaneous value. In the event of a power failure, the measured data will remain in memory. The power supply of the module from the instrument body is subordinated to the M08 or M32 module.
Parameters
power voltage:
current measurement in the range:
accuracy:
other functions:
dimensions (hxw):
230 V AC / 50 Hz
70 mA - 200 A AC
1% +/- 1 digit
hysteresis function and adjustable limit values
200 x 240 mm

M93- Compressed air outlet module, two valves, nominal flow 600 l / min
Description
The M93 module contains two independent compressed air valves with a 0.1 bar to 10 bar upstream control valve. The type of valve used allows a maximum air flow of 600 l / min. Each of the valves is led to two outlets, between which the air is switched.
Parameters
nominal air flow:
pressure relief valve outlet pressure range:
supply air pressure range:
valve function:
dimensions (hxw):
600 l / min
0.1 bar - 10 bar
10 - 12 bar
output "A", off, output "B"
200 x 240 mm

M94- Module of single-phase digital ammeter up to 15A AC and voltmeter up to 250V AC
Description
The M94 module includes a digital ammeter and voltmeter for measuring AC current and voltage over a wide range of values. The ammeter measures the rms value of the current and stores the maximum, average and instantaneous value. The voltmeter measures the effective value of the voltage and stores in memory the min. and max. values. In the event of a power failure, the measured data will remain in memory. The power supply of the module from the instrument body is subordinated to the M08 or M32 module.
Parameters
supply voltage of both devices:
current measurement in the range:
other ammeter functions:
voltage measurement in the range:
accuracy:
network connection:
dimensions (hxw):
230 V AC / 50 Hz
70 mA - 200 A AC
hysteresis function and adjustable limit values
10 - 600 V AC
1% +/- 1 digit
1 phase, two-wire (each of the devices separately)
200 x 240 mm

M95- 3-phase programmable digital multimeter module
Description
The M95 module contains a three-phase network analyzer that can display up to 22 different network parameters. The measured values are displayed on four separate displays. It offers six different methods for energy calculation, two electricity meters, two digital inputs, two pulse outputs, display of maximum and minimum measured values, communication via RS-485.
The power supply of the module from the instrument body is subordinated to the M08 or M32 module.
Parameters
supply voltage of both devices:
current display in range:
ammeter range:
voltage measurement in the range:
accuracy:
data communication:
dimensions (hxw):
230 V AC / 50 Hz
50 mA - 10 kA AC
50 mA - 5.5 A AC
10 - 300 V AC (LN), 10 - 500V AC (LL)
1% +/- 1 digit
RS-485 MODBUS RTU
200 x 180 mm

M98- 3-phase isolating transformer module 3 x 230/400 V, 3A
Description
The M98 module contains a three-phase isolating transformer with a maximum consumption of 3A in three phases. It is used to separate the modules in the body from the external network, the transformer is located inside the instrument body.
Power supply of the module from the instrument body is subordinate to the M32 module.
Parameters
power voltage:
output voltage:
output current:
insurance:
dimensions (hxw):
3 x 230 V / 400 V AC / 50 Hz
3 x 230 V / 400 V AC / 50 Hz
3 x 3 A AC
fuses
inside the body, does not require any space in the front panel of the body
M99- Module DC stabilized power supply 15V / 5A

Description
The M99 module contains a 15 V DC power supply with a maximum consumption of 5A. It is equipped with short-circuit and overload protection, power indicator and rocker switch. Voltage from the source is applied to the sockets. It is used to separate the modules in the body from the external network, the transformer is located inside the instrument body.
Power supply of the module from the instrument body is subordinate to the M32 module.
Parameters
power voltage:
output voltage:
output current:
insurance:
dimensions (hxw):
230 V / 50 Hz
15 V DC
5 A DC
electronic
200 x 120 mm
M100- DC and AC safety sockets module and 1 x LAN-RJ45 data interface

Description
The M100 module contains a pair of sockets for AC and DC voltage output (must be connected to a source that is not part of the module) and an RJ45 Cat 5e data socket. The socket is completed with a 5 m long Ethernet Cat5e data connection cable.
Parameters
output voltage at the sockets:
output current at sockets:
data connection:
dimensions (hxw):
up to 230 V / 50 Hz max.
up to 10 A max.
RJ45 socket, Cat5e and Cat5e UTP Ethernet cable (5 m)
200 x 60 mm
M101- Autotransformer module 3f, 0 - 100% Uprim / 4A

Description
The M101 module contains a three-phase autotransformer with a variable output voltage, adjustable in the range of 0 to 100% of the input voltage. The output current can be up to 4 A. The module is protected against short-circuit and overload of the output terminals by a three-phase circuit breaker 3 x 4 A.
Parameters
power voltage:
output voltage:
output current:
insurance:
dimensions (hxw):
any voltage up to 3 x 400/230 V / 50 Hz
0 - 100% of input voltage
4 A max
circuit breaker 3 x 4 A / C
200 x 450 mm

M102- AC power supply module 6 - 12 - 24 - 48V / 2,0A
Description
The VarioLab + M102 module is a fixed source of low AC voltage with the possibility of switching the value of the output voltage in the range of 6 - 12 - 24 - 48 V / 2.0 A with a rotary switch. The power supply is equipped with its own switch and output voltage signaling by LED indicator. Voltage is applied to the safety instrument terminals. Secured by an input fuse.
Parameters
power voltage:
output voltage:
fixed current:
input protection:
dimensions (hxw):
230 V / 50 Hz
6 - 12 - 24 - 48 V DC
2 A
fuse T 250 V / 0.4 A
200 x 120 mm
M103-06 - Module of 4 sockets 230V CEE 5/7, 16A with circuit breaker 6 A / B

Description
The VarioLab + M103 module contains two single 230 V CEE 5/7, 16A sockets with its own 6 A circuit breaker. The module does not have its own circuit breaker and is subject to the M08 or M32 module for safety reasons. The voltage in the sockets is indicated by a light on the module. The sockets are rotated 45 ° for easy handling of the plugs.
Parameters
power voltage:
maximum current:
insurance:
dimensions (hxw):
230 V / 50 Hz
6 And in total
1 phase circuit breaker 6 A, characteristic B
200 x 120 mm
M103-10 - Module of 4 sockets 230V CEE 5/7, 16A with circuit breaker 10 A / B

Description
The VarioLab + M103 module contains two single 230 V CEE 5/7, 16A sockets with its own 10 A circuit breaker. The module does not have its own circuit breaker and is subject to the M08 or M32 module for safety reasons. To maintain selectivity, the value of the circuit breaker of the M08 or M32 module must be at least 16 A. The voltage in the sockets is indicated by a light on the module. The sockets are rotated 45 ° for easy handling of the plugs.
Parameters
power voltage:
maximum current:
insurance:
dimensions (hxw):
230 V / 50 Hz
10 And in total
1 phase circuit breaker 10 A, characteristic B
200 x 120 mm
M103-10 - Module of 4 sockets 230V CEE 5/7, 16A with circuit breaker 10 A / B

Description
The VarioLab + M103 module contains two single 230 V CEE 5/7, 16A sockets with its own 10 A circuit breaker. The module does not have its own circuit breaker and is subject to the M08 or M32 module for safety reasons. To maintain selectivity, the value of the circuit breaker of the M08 or M32 module must be at least 16 A. The voltage in the sockets is indicated by a light on the module. The sockets are rotated 45 ° for easy handling of the plugs.
Parameters
power voltage:
maximum current:
insurance:
dimensions (hxw):
230 V / 50 Hz
10 And in total
1 phase circuit breaker 10 A, characteristic B
200 x 120 mm